{"id":1497,"date":"2026-02-25T12:36:45","date_gmt":"2026-02-25T02:36:45","guid":{"rendered":"https:\/\/nuflow.net\/northwest-sydney\/?p=1497"},"modified":"2026-02-25T14:34:11","modified_gmt":"2026-02-25T04:34:11","slug":"stormwater-pipe-rehabilitation-high-school","status":"publish","type":"post","link":"https:\/\/nuflow.net\/northwest-sydney\/stormwater-pipe-rehabilitation-high-school\/","title":{"rendered":"Stormwater Pipe Rehabilitation"},"content":{"rendered":"\n<p><strong>NUFLOW NORTHWEST SYDNEY <\/strong><br>EDUCATION PRECINCT | NSW DEPARTMENT OF EDUCATION<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">PROJECT OVERVIEW<\/h2>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-28f84493 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<p>Nuflow was engaged to address persistent flooding and drainage issues at a High School, specifically behind C Block near the staff car park. The existing 225mm PVC stormwater line had been compromised by heavy silt deposits, buried pits, and extensive tree root intrusions. These failures caused repeated water pooling during rain events, creating safety hazards and disrupting school operations. The project required a trenchless, long-term solution that could be delivered quickly to minimise disruption on site.<\/p>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<figure class=\"wp-block-image size-full is-resized\"><img fetchpriority=\"high\" decoding=\"async\" width=\"368\" height=\"339\" src=\"https:\/\/nuflow.net\/northwest-sydney\/wp-content\/uploads\/sites\/69\/2026\/02\/stormwater-pit-grate-access-pre-relining-inspection.jpg\" alt=\"\" class=\"wp-image-1500\" style=\"width:388px;height:auto\" srcset=\"https:\/\/nuflow.net\/northwest-sydney\/wp-content\/uploads\/sites\/69\/2026\/02\/stormwater-pit-grate-access-pre-relining-inspection.jpg 368w, https:\/\/nuflow.net\/northwest-sydney\/wp-content\/uploads\/sites\/69\/2026\/02\/stormwater-pit-grate-access-pre-relining-inspection-300x276.jpg 300w\" sizes=\"(max-width: 368px) 100vw, 368px\" \/><\/figure>\n<\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-28f84493 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<figure class=\"wp-block-image size-full\"><img decoding=\"async\" width=\"369\" height=\"499\" src=\"https:\/\/nuflow.net\/northwest-sydney\/wp-content\/uploads\/sites\/69\/2026\/02\/stormwater-pipe-diameter-measurement-pre-installation-assessment.jpg\" alt=\"\" class=\"wp-image-1501\" srcset=\"https:\/\/nuflow.net\/northwest-sydney\/wp-content\/uploads\/sites\/69\/2026\/02\/stormwater-pipe-diameter-measurement-pre-installation-assessment.jpg 369w, https:\/\/nuflow.net\/northwest-sydney\/wp-content\/uploads\/sites\/69\/2026\/02\/stormwater-pipe-diameter-measurement-pre-installation-assessment-222x300.jpg 222w\" sizes=\"(max-width: 369px) 100vw, 369px\" \/><\/figure>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<h2 class=\"wp-block-heading\">CHALLENGE<\/h2>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>Frequent Flooding<\/strong> \u2013 Drainage failures caused flooding and erosion behind C Block, especially after new strip drains were installed.<\/li>\n\n\n\n<li><strong>Obstructed Pits<\/strong> \u2013 Existing stormwater pits were buried and letting large amounts of soil wash into the line.<\/li>\n\n\n\n<li><strong>Pipe Defects<\/strong> \u2013 Rubber ring joints had failed, allowing tree roots to grow inside and deform the pipe.<\/li>\n\n\n\n<li><strong>Heavy Silt Build-Up <\/strong>\u2013 Significant sediment reduced pipe capacity and stormwater flow.<\/li>\n\n\n\n<li><strong>Tight Timeframes <\/strong>\u2013 Works needed to be completed quickly in order to restore safe drainage around the school.<\/li>\n<\/ul>\n<\/div>\n<\/div>\n\n\n\n<h2 class=\"wp-block-heading\">THE SOLUTION<\/h2>\n\n\n\n<p>To address the drainage failures and restore the stormwater system, Nuflow implemented a combination of trenchless rehabilitation methods and site improvements:<\/p>\n\n\n\n<ol class=\"wp-block-list\">\n<li><strong>Comprehensive Cleaning &amp; CCTV Inspection<\/strong> &#8211; The team began with high-pressure jetting (HPJ) to remove heavy silt and root blockages, restoring temporary flow and making the line suitable for inspection. Using CCTV technology, each section of the pipe was mapped and defects were documented, including failed joints and areas of deformation that required structural rehabilitation.<\/li>\n\n\n\n<li><strong>Pit Excavation &amp; Restoration<\/strong> &#8211; A buried stormwater pit was excavated, cleaned, and reinstated. A retaining wall was proposed around the pit to ensure long-term accessibility for future maintenance, preventing a repeat of soil ingress into the system.<\/li>\n\n\n\n<li><strong>Blueline Relining with Ready Cure<\/strong> &#8211; Nuflow\u2019s Blueline system was installed across two key sections of the stormwater line. To minimise disruption, the Ready Cure method was applied, using 65-degree hot water to cure the liner within approximately 2.5 hours instead of the standard 24\u201336. This fast curing ensured the line was back in service on the same day, keeping the school operational.<\/li>\n\n\n\n<li><strong>Robotic Cutting &amp; Junction Reinstatement<\/strong> &#8211; A junction that had been lined over was reopened using robotic cutting technology, followed by the use of a hydraulic grabber to remove lodged debris. This restored full serviceability of the junction and ensured stormwater could flow through multiple outlets.<\/li>\n\n\n\n<li><strong>Proposed Surface Drainage Enhancement<\/strong> &#8211; To further improve site conditions, the installation of an aggregate drain was recommended along the building slab. The design, 500mm deep and wide, would be filled with blue metal aggregate and finished with decorative stones, providing both effective drainage and an improved site appearance.<\/li>\n<\/ol>\n\n\n\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" width=\"1024\" height=\"384\" src=\"https:\/\/nuflow.net\/northwest-sydney\/wp-content\/uploads\/sites\/69\/2026\/02\/school-stormwater-drain-access-safety-cones-excavation-1024x384.avif\" alt=\"\" class=\"wp-image-1499\" srcset=\"https:\/\/nuflow.net\/northwest-sydney\/wp-content\/uploads\/sites\/69\/2026\/02\/school-stormwater-drain-access-safety-cones-excavation-1024x384.avif 1024w, https:\/\/nuflow.net\/northwest-sydney\/wp-content\/uploads\/sites\/69\/2026\/02\/school-stormwater-drain-access-safety-cones-excavation-300x113.avif 300w, https:\/\/nuflow.net\/northwest-sydney\/wp-content\/uploads\/sites\/69\/2026\/02\/school-stormwater-drain-access-safety-cones-excavation-768x288.avif 768w, https:\/\/nuflow.net\/northwest-sydney\/wp-content\/uploads\/sites\/69\/2026\/02\/school-stormwater-drain-access-safety-cones-excavation.avif 1505w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\">THE RESULTS<\/h2>\n\n\n\n<p>The rehabilitation works successfully restored the stormwater system servicing the rear of C Block at the High School. The 225mm PVC line, previously compromised by tree root intrusions, failed joints, and heavy silt build-up, was structurally reinforced through Blueline relining. The use of Ready Cure technology enabled the liners to be cured and the line returned to service within a single day, significantly reducing downtime and disruption to school operations. Excavated pits were reinstated and prepared for long-term accessibility, while robotic cutting ensured that critical junctions remained open and fully functional. Final CCTV inspections confirmed that the system is now clear, watertight, and performing as designed, with capacity restored and future intrusion risks minimised. The site was left safe, operational, and better prepared for future storm events, ensuring a reliable and long-term solution for the school community.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">NUFLOW\u2019S AGING INFRASTRUCTURE MAINTENANCE AND REHABILITATION<\/h2>\n\n\n\n<p>For information on how Nuflow can help maintain and rehabilitate your potable water assets\u2014 including pressure main relining, concrete pipeline repairs, and trenchless rehabilitation of critical supply infrastructure\u2014contact our team of specialists. We deliver safe, compliant solutions for even the most complex potable water pipe repair projects.<\/p>\n","protected":false},"excerpt":{"rendered":"<p>Nuflow was engaged to fix persistent flooding and drainage failures behind C Block at a high school, where a compromised 225 mm PVC stormwater line was overwhelmed by silt, failed joints and root intrusions. Using CCTV inspection, high-pressure cleaning and Blueline trenchless relining with Ready Cure technology, NuFlow restored structural integrity and safe stormwater flow with minimal disruption to school operations.<\/p>\n","protected":false},"author":64,"featured_media":1504,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"content-type":"","footnotes":""},"categories":[15],"tags":[],"class_list":["post-1497","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-case-studies"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v27.2 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Stormwater Pipe Rehabilitation High School | Nuflow Northwest Sydney<\/title>\n<meta name=\"description\" content=\"Nuflow Northwest Sydney restored stormwater flow behind C Block at a NSW high school using CCTV inspection, cleaning, and fast-cure trenchless Blueline relining to eliminate flooding hazards with minimal disruption.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/nuflow.net\/northwest-sydney\/stormwater-pipe-rehabilitation-high-school\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Stormwater Pipe Rehabilitation High School | Nuflow Northwest Sydney\" \/>\n<meta property=\"og:description\" content=\"Nuflow Northwest Sydney restored stormwater flow behind C Block at a NSW high school using CCTV inspection, cleaning, and fast-cure trenchless Blueline relining to eliminate flooding hazards with minimal disruption.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/nuflow.net\/northwest-sydney\/stormwater-pipe-rehabilitation-high-school\/\" \/>\n<meta property=\"og:site_name\" content=\"Nuflow Northwest Sydney\" \/>\n<meta property=\"article:published_time\" content=\"2026-02-25T02:36:45+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2026-02-25T04:34:11+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/nuflow.net\/northwest-sydney\/wp-content\/uploads\/sites\/69\/2026\/02\/stormwater-pipe-liner-preparation-resin-impregnated-liner-nuflow.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"468\" \/>\n\t<meta property=\"og:image:height\" content=\"242\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"studio\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"studio\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"4 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\/\/nuflow.net\/northwest-sydney\/stormwater-pipe-rehabilitation-high-school\/#article\",\"isPartOf\":{\"@id\":\"https:\/\/nuflow.net\/northwest-sydney\/stormwater-pipe-rehabilitation-high-school\/\"},\"author\":{\"name\":\"studio\",\"@id\":\"https:\/\/nuflow.net\/northwest-sydney\/#\/schema\/person\/0738a219c6d4f5a3b7760cc845b920be\"},\"headline\":\"Stormwater Pipe Rehabilitation\",\"datePublished\":\"2026-02-25T02:36:45+00:00\",\"dateModified\":\"2026-02-25T04:34:11+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\/\/nuflow.net\/northwest-sydney\/stormwater-pipe-rehabilitation-high-school\/\"},\"wordCount\":638,\"commentCount\":0,\"image\":{\"@id\":\"https:\/\/nuflow.net\/northwest-sydney\/stormwater-pipe-rehabilitation-high-school\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/nuflow.net\/northwest-sydney\/wp-content\/uploads\/sites\/69\/2026\/02\/stormwater-pipe-liner-preparation-resin-impregnated-liner-nuflow.jpg\",\"articleSection\":[\"Case Studies\"],\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\/\/nuflow.net\/northwest-sydney\/stormwater-pipe-rehabilitation-high-school\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\/\/nuflow.net\/northwest-sydney\/stormwater-pipe-rehabilitation-high-school\/\",\"url\":\"https:\/\/nuflow.net\/northwest-sydney\/stormwater-pipe-rehabilitation-high-school\/\",\"name\":\"Stormwater Pipe Rehabilitation High School | Nuflow Northwest Sydney\",\"isPartOf\":{\"@id\":\"https:\/\/nuflow.net\/northwest-sydney\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/nuflow.net\/northwest-sydney\/stormwater-pipe-rehabilitation-high-school\/#primaryimage\"},\"image\":{\"@id\":\"https:\/\/nuflow.net\/northwest-sydney\/stormwater-pipe-rehabilitation-high-school\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/nuflow.net\/northwest-sydney\/wp-content\/uploads\/sites\/69\/2026\/02\/stormwater-pipe-liner-preparation-resin-impregnated-liner-nuflow.jpg\",\"datePublished\":\"2026-02-25T02:36:45+00:00\",\"dateModified\":\"2026-02-25T04:34:11+00:00\",\"author\":{\"@id\":\"https:\/\/nuflow.net\/northwest-sydney\/#\/schema\/person\/0738a219c6d4f5a3b7760cc845b920be\"},\"description\":\"Nuflow Northwest Sydney restored stormwater flow behind C Block at a NSW high school using CCTV inspection, cleaning, and fast-cure trenchless Blueline relining to eliminate flooding hazards with minimal disruption.\",\"breadcrumb\":{\"@id\":\"https:\/\/nuflow.net\/northwest-sydney\/stormwater-pipe-rehabilitation-high-school\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/nuflow.net\/northwest-sydney\/stormwater-pipe-rehabilitation-high-school\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/nuflow.net\/northwest-sydney\/stormwater-pipe-rehabilitation-high-school\/#primaryimage\",\"url\":\"https:\/\/nuflow.net\/northwest-sydney\/wp-content\/uploads\/sites\/69\/2026\/02\/stormwater-pipe-liner-preparation-resin-impregnated-liner-nuflow.jpg\",\"contentUrl\":\"https:\/\/nuflow.net\/northwest-sydney\/wp-content\/uploads\/sites\/69\/2026\/02\/stormwater-pipe-liner-preparation-resin-impregnated-liner-nuflow.jpg\",\"width\":468,\"height\":242},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/nuflow.net\/northwest-sydney\/stormwater-pipe-rehabilitation-high-school\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/nuflow.net\/northwest-sydney\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Stormwater Pipe Rehabilitation\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/nuflow.net\/northwest-sydney\/#website\",\"url\":\"https:\/\/nuflow.net\/northwest-sydney\/\",\"name\":\"Nuflow Northwest Sydney\",\"description\":\"Blocked Drain &amp; Pipe Relining Specialists\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/nuflow.net\/northwest-sydney\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Person\",\"@id\":\"https:\/\/nuflow.net\/northwest-sydney\/#\/schema\/person\/0738a219c6d4f5a3b7760cc845b920be\",\"name\":\"studio\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/secure.gravatar.com\/avatar\/2ab66c3ca50d77d00bb6703c897fef66041e32e439ef80495ebebb28a1ff7e3d?s=96&d=mm&r=g\",\"url\":\"https:\/\/secure.gravatar.com\/avatar\/2ab66c3ca50d77d00bb6703c897fef66041e32e439ef80495ebebb28a1ff7e3d?s=96&d=mm&r=g\",\"contentUrl\":\"https:\/\/secure.gravatar.com\/avatar\/2ab66c3ca50d77d00bb6703c897fef66041e32e439ef80495ebebb28a1ff7e3d?s=96&d=mm&r=g\",\"caption\":\"studio\"}}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Stormwater Pipe Rehabilitation High School | Nuflow Northwest Sydney","description":"Nuflow Northwest Sydney restored stormwater flow behind C Block at a NSW high school using CCTV inspection, cleaning, and fast-cure trenchless Blueline relining to eliminate flooding hazards with minimal disruption.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/nuflow.net\/northwest-sydney\/stormwater-pipe-rehabilitation-high-school\/","og_locale":"en_US","og_type":"article","og_title":"Stormwater Pipe Rehabilitation High School | Nuflow Northwest Sydney","og_description":"Nuflow Northwest Sydney restored stormwater flow behind C Block at a NSW high school using CCTV inspection, cleaning, and fast-cure trenchless Blueline relining to eliminate flooding hazards with minimal disruption.","og_url":"https:\/\/nuflow.net\/northwest-sydney\/stormwater-pipe-rehabilitation-high-school\/","og_site_name":"Nuflow Northwest Sydney","article_published_time":"2026-02-25T02:36:45+00:00","article_modified_time":"2026-02-25T04:34:11+00:00","og_image":[{"width":468,"height":242,"url":"https:\/\/nuflow.net\/northwest-sydney\/wp-content\/uploads\/sites\/69\/2026\/02\/stormwater-pipe-liner-preparation-resin-impregnated-liner-nuflow.jpg","type":"image\/jpeg"}],"author":"studio","twitter_card":"summary_large_image","twitter_misc":{"Written by":"studio","Est. reading time":"4 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/nuflow.net\/northwest-sydney\/stormwater-pipe-rehabilitation-high-school\/#article","isPartOf":{"@id":"https:\/\/nuflow.net\/northwest-sydney\/stormwater-pipe-rehabilitation-high-school\/"},"author":{"name":"studio","@id":"https:\/\/nuflow.net\/northwest-sydney\/#\/schema\/person\/0738a219c6d4f5a3b7760cc845b920be"},"headline":"Stormwater Pipe Rehabilitation","datePublished":"2026-02-25T02:36:45+00:00","dateModified":"2026-02-25T04:34:11+00:00","mainEntityOfPage":{"@id":"https:\/\/nuflow.net\/northwest-sydney\/stormwater-pipe-rehabilitation-high-school\/"},"wordCount":638,"commentCount":0,"image":{"@id":"https:\/\/nuflow.net\/northwest-sydney\/stormwater-pipe-rehabilitation-high-school\/#primaryimage"},"thumbnailUrl":"https:\/\/nuflow.net\/northwest-sydney\/wp-content\/uploads\/sites\/69\/2026\/02\/stormwater-pipe-liner-preparation-resin-impregnated-liner-nuflow.jpg","articleSection":["Case Studies"],"inLanguage":"en-US","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/nuflow.net\/northwest-sydney\/stormwater-pipe-rehabilitation-high-school\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/nuflow.net\/northwest-sydney\/stormwater-pipe-rehabilitation-high-school\/","url":"https:\/\/nuflow.net\/northwest-sydney\/stormwater-pipe-rehabilitation-high-school\/","name":"Stormwater Pipe Rehabilitation High School | Nuflow Northwest Sydney","isPartOf":{"@id":"https:\/\/nuflow.net\/northwest-sydney\/#website"},"primaryImageOfPage":{"@id":"https:\/\/nuflow.net\/northwest-sydney\/stormwater-pipe-rehabilitation-high-school\/#primaryimage"},"image":{"@id":"https:\/\/nuflow.net\/northwest-sydney\/stormwater-pipe-rehabilitation-high-school\/#primaryimage"},"thumbnailUrl":"https:\/\/nuflow.net\/northwest-sydney\/wp-content\/uploads\/sites\/69\/2026\/02\/stormwater-pipe-liner-preparation-resin-impregnated-liner-nuflow.jpg","datePublished":"2026-02-25T02:36:45+00:00","dateModified":"2026-02-25T04:34:11+00:00","author":{"@id":"https:\/\/nuflow.net\/northwest-sydney\/#\/schema\/person\/0738a219c6d4f5a3b7760cc845b920be"},"description":"Nuflow Northwest Sydney restored stormwater flow behind C Block at a NSW high school using CCTV inspection, cleaning, and fast-cure trenchless Blueline relining to eliminate flooding hazards with minimal disruption.","breadcrumb":{"@id":"https:\/\/nuflow.net\/northwest-sydney\/stormwater-pipe-rehabilitation-high-school\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/nuflow.net\/northwest-sydney\/stormwater-pipe-rehabilitation-high-school\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/nuflow.net\/northwest-sydney\/stormwater-pipe-rehabilitation-high-school\/#primaryimage","url":"https:\/\/nuflow.net\/northwest-sydney\/wp-content\/uploads\/sites\/69\/2026\/02\/stormwater-pipe-liner-preparation-resin-impregnated-liner-nuflow.jpg","contentUrl":"https:\/\/nuflow.net\/northwest-sydney\/wp-content\/uploads\/sites\/69\/2026\/02\/stormwater-pipe-liner-preparation-resin-impregnated-liner-nuflow.jpg","width":468,"height":242},{"@type":"BreadcrumbList","@id":"https:\/\/nuflow.net\/northwest-sydney\/stormwater-pipe-rehabilitation-high-school\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/nuflow.net\/northwest-sydney\/"},{"@type":"ListItem","position":2,"name":"Stormwater Pipe Rehabilitation"}]},{"@type":"WebSite","@id":"https:\/\/nuflow.net\/northwest-sydney\/#website","url":"https:\/\/nuflow.net\/northwest-sydney\/","name":"Nuflow Northwest Sydney","description":"Blocked Drain &amp; Pipe Relining Specialists","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/nuflow.net\/northwest-sydney\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Person","@id":"https:\/\/nuflow.net\/northwest-sydney\/#\/schema\/person\/0738a219c6d4f5a3b7760cc845b920be","name":"studio","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/secure.gravatar.com\/avatar\/2ab66c3ca50d77d00bb6703c897fef66041e32e439ef80495ebebb28a1ff7e3d?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/2ab66c3ca50d77d00bb6703c897fef66041e32e439ef80495ebebb28a1ff7e3d?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/2ab66c3ca50d77d00bb6703c897fef66041e32e439ef80495ebebb28a1ff7e3d?s=96&d=mm&r=g","caption":"studio"}}]}},"_links":{"self":[{"href":"https:\/\/nuflow.net\/northwest-sydney\/wp-json\/wp\/v2\/posts\/1497","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/nuflow.net\/northwest-sydney\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/nuflow.net\/northwest-sydney\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/nuflow.net\/northwest-sydney\/wp-json\/wp\/v2\/users\/64"}],"replies":[{"embeddable":true,"href":"https:\/\/nuflow.net\/northwest-sydney\/wp-json\/wp\/v2\/comments?post=1497"}],"version-history":[{"count":3,"href":"https:\/\/nuflow.net\/northwest-sydney\/wp-json\/wp\/v2\/posts\/1497\/revisions"}],"predecessor-version":[{"id":1586,"href":"https:\/\/nuflow.net\/northwest-sydney\/wp-json\/wp\/v2\/posts\/1497\/revisions\/1586"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/nuflow.net\/northwest-sydney\/wp-json\/wp\/v2\/media\/1504"}],"wp:attachment":[{"href":"https:\/\/nuflow.net\/northwest-sydney\/wp-json\/wp\/v2\/media?parent=1497"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/nuflow.net\/northwest-sydney\/wp-json\/wp\/v2\/categories?post=1497"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/nuflow.net\/northwest-sydney\/wp-json\/wp\/v2\/tags?post=1497"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}